CS series oil-free screw compressor overseas project successfully delivered

Aertrans Machinery CS series oil-free screw compressor overseas project was successfully delivered On April 11, 2026, Jiangsu Aertrans Machinery successfully delivered the overseas project (2 units of CS series screw compressors). After more than 120 days of hard work day and night and overcoming difficulties, the equipment was officially shipped to the destination. This marked the first time that our team has completely introduced the product to the overseas market. Complete oil-free screw compressor: localized replacement, energy saving and cost reduction Aertrans The CS series oil-free screw compressor shipped by Machinery this time has excellent performance and has the following advantages: 1. Low maintenance cost: only the lubricating oil is replaced regularly, and the use of our company's localized replacement saves 30% to 50% of the cost; 2. Stable and reliable: core components are carefully configured to ensure long-term continuous operation. 3. Customized adaptation: Flexibly adjust the configuration according to customer on-site scenarios to meet diverse needs. 4. Easy to install: The components are installed in place when the whole machine is supplied, and it can be installed quickly on site. It only requires power supply and connection.

READ MORE
2026 04-22
Picture 2.png
Compressor failure caused by check valve

Compressor failure caused by check valve

READ MORE
2026 02-26
Lubricating oil.jpg
The importance of lubricants

The importance of lubricants

READ MORE
2025 12-10
CS low voltage.png
Abnormal compressor vibration failure

Abnormal compressor vibration failure

READ MORE
2025 10-28
Picture 3.png
A series of faults caused by insufficient repair of synchronization gears

A series of faults caused by insufficient repair of synchronization gears 1. Case background A customer had a self-repaired Roots blower that experienced abnormal vibration and sound during startup and operation, and was forced to shut down, which affected production. Preliminary inspection of the equipment showed that the vibration value on the drive side seriously exceeded the standard. The customer then sent the equipment to our company for in-depth disassembly and repair. 2. Fault phenomenon and preliminary judgment After the equipment arrived at the factory, our maintenance engineers conducted a preliminary operation test (under the premise of ensuring safety), and found that the vibration at the drive end was indeed large, far exceeding the standard value. Based on experience, our engineers determined that the root cause of the fault was likely to be the failure of the rotor dynamic balance, bearing damage, or rotor meshing, and decided to immediately disassemble and inspect it. 3. In-depth disassembly and failure analysis Cause of failure: After disassembly, it was found that the root cause of the equipment failure was that the customer's previous repair process for the synchronization gear was not in place or the repair plan was technically undesirable. Evidence of failure: while dismantling

READ MORE